As industrial cranes expand in application, enhanced maintenance management is essential to maximize lifting equipment performance and ensure safe, reliable operation. During routine service, vulnerable industrial crane components, including wire ropes and pulleys, reducer gears, couplings, brakes, three-phase AC motors, high-voltage cabinets, and transformers, are prone to malfunctions. We will implement targeted maintenance practices to reduce failure rates, sustain optimal crane performance, improve port operational efficiency, and secure production safety.

1. Faults of Wire Ropes and Pulleys
Wire rope pulleys are core load-bearing components of industrial cranes. Typical defects include damaged bearings, cracked or excessively worn pulley rims. Continuous extrusion and friction between wire ropes and pulleys gradually wear down pulley rims. Once wear exceeds the design tolerance, compressive load from wire ropes surpasses the pulley’s bearing capacity and results in rim cracking.
2. Reducer Gear Failures
As a fundamental transmission part, the reducer transmits torque via gear meshing to reduce motor rotating speed to rated working parameters. Common gear defects include scuffing of tooth surfaces, broken gear teeth, and severe abrasive wear on tooth flanks during torque transmission.
3. Coupling Malfunctions
For gear couplings, meshing tooth surfaces suffer frequent abrasion, tooth chipping or tooth breakage. In the case of jaw-type flexible couplings, the polyurethane spider element wears rapidly, ages prematurely or develops fatigue cracks under prolonged industrial crane operation. For elastic pin couplings, the rubber buffer sleeves experience heavy wear and pin loosening after long-term service, triggering excessive vibration and abnormal noise during power transmission and hindering normal equipment operation. In addition, fracture of coupling connecting bolts may lead to consequential mechanical breakdowns.
4. Brake Faults
Brakes of industrial cranes are prone to various failures in practical production: ① Abnormal wear of brake linings shortens service life and leads to frequent replacements; ② Excessive brake clearance deteriorates braking performance and may even result in complete braking failure; ③ Excessively high temperature of brake drums during braking dissolves and ages the elastic rubber sleeves of connecting pins; ④ Jamming at the hinge points of brake levers impedes normal brake opening, posing severe safety hazards to lifting and loading operations.

5. Three-Phase AC Motor Faults
Three-phase AC motors convert electric energy into mechanical energy for industrial crane operation yet are susceptible to breakdowns under various operating conditions. Excessively high supply voltage boosts exciting current and causes overheating. Excessive heat damages winding insulation and raises the risk of insulation breakdown. Conversely, low supply voltage drastically reduces electromagnetic torque. If the load torque remains unchanged, the rotor speed drops with increased slip, resulting in motor overload and further heat buildup. Prolonged overheating together with ambient moisture accelerates insulation aging and shortens the motor’s service life.
6. Abnormal Noise at Boom Hinge Points
Frequent heavy impact loads accelerate component aging and damage, triggering abnormal noise during luffing operations. For instance, foreign granular or powdery debris trapped at the lower boom hinge together with broken or loose retaining bolts on the shaft end plate creates unusual noise, disrupts normal industrial crane operation and brings potential safety risks.
1. Maintenance of Wire Rope Pulley Blocks
To guarantee stable and safe operation of pulley blocks, overloading is strictly forbidden during industrial crane service to avoid excessive load and subsequent bearing damage. The wire rope shall be lubricated regularly to reduce friction between ropes and pulleys and prevent severe abrasion on pulley rims and grooves. Pulleys must be scrapped and replaced when uneven groove wear reaches 3 mm or more, cracks emerge, or wall thickness loss exceeds one-fifth of the original dimension.
2. Maintenance of Reducer Gears
Overload operation is prohibited for reducers; startup and braking shall be smooth and gradual, and reverse rotation before full shutdown is not allowed except for emergencies. Qualified lubricating oil shall be replenished periodically and the housing cleaned timely. Regular oil quality inspection helps monitor gear wear and implement targeted maintenance to curb accelerated abrasion and potential breakdown accidents.
3. Maintenance of Couplings
Internal and external teeth of gear couplings wear over long-term running, hence regular lubrication and maintenance are mandatory. For flexible couplings, frequent inspections on elastic elements and pins are required with immediate replacement of damaged elastomers; all fastening bolts shall be retightened routinely to avoid malfunction caused by loose fasteners. Precise alignment is required during installation to extend service life, and periodic grease filling ensures sufficient lubrication at meshing tooth clearances for wear reduction. Industrial crane operation should be gentle and steady. Abnormal excessive vibration or noise requires immediate shutdown for inspection and repair.
4. Maintenance of Brakes
Routine inspections are essential for brake fault prevention focusing on four items:
① Check hinge pins for severe wear or jamming and connecting parts for looseness.
② Verify the clearance between brake lining and brake drum meets specification.
③ Confirm proper working condition of the hydraulic system.
④ Inspect linings and drums for surface wear and oil contamination. These checks facilitate effective brake condition monitoring. All brake hinges need regular lubrication and appropriate stroke adjustment to secure reliable and safe braking performance.

5. Maintenance of Three-Phase AC Motors
Power supply must be cut off prior to any maintenance for operator and equipment safety. Allow hot components to cool down completely after motor stop before servicing. For long-term idle industrial cranes, run the motor at least once per month to keep built-in heaters functional and inspect for component damage. Monitor operating smell, noise and vibration continuously during use; shut down immediately upon burnt odour and examine windings thoroughly against burnout damage.
6. Maintenance for Lower Boom Hinges
Daily patrol is needed to eliminate abnormal noises at lower boom hinges by tightening shaft-end retaining bolts and clearing foreign debris. Replace rolling bearings after load calculation once abnormal noise occurs, following the below working procedures:
① Set the industrial crane’s luffing radius at around 25 m for balance; fasten the movable counterweight of the boom system to rear bracket lifting holes of the A-frame via two Φ32 mm wire ropes and hand chain hoists to adjust axial load on hinge pins;
② Weld a base with 20 mm steel plate in front of lower boom hinge, plus vertical ribs roughly 60 mm upward from the hinge to match the base position;
Place a 25-ton jack on the fabricated base for supporting purpose.
Industrial cranes occupy a vital position in cargo loading and unloading at ports and docks. However, their service environment features high humidity and dense dust, making the machines susceptible to environment-induced failures; improper manual operation will also inflict serious damage on equipment. Accordingly, equipment management units shall conduct full analysis on prevalent in-service faults, draw up targeted maintenance schedules and carry out practical upkeep and repair work. Regular inspection of industrial crane component working conditions helps cut down failure frequency and guarantees safe, efficient and dependable industrial crane operation.